A UF skid is a modular, pre-assembled ultrafiltration system mounted on a steel frame, integrating membrane modules, pumps, controls, and piping for plug-and-play operation. It uses 0.01–0.1μm semi-permeable membranes to remove bacteria, colloids, and macromolecules from liquids, suitable for water treatment, wastewater reuse, and industrial processes.
Core Components

Membrane Modules
★ Hollow-fiber PVDF membranes (50–100 m² surface area/set) for high flux (15–30 L/m²·h).
★ Flat-sheet modules for high-viscosity fluids (e.g., food processing wastewater).
Pressure Pumps
★ Centrifugal pumps (0.3–0.5 MPa) with VFD, supporting 50–5,000 m³/d flow.
Control System
★ PLC panel monitoring TMP (transmembrane pressure), triggering backwash (30–60 min intervals) and CIP (monthly chemical cleaning).
Piping & Valves
★ Stainless steel piping (DN50–DN200) with quick-connect fittings for feed water, permeate, and backwash lines.

Advantages
- Modular Design: Pre-fabricated skids reduce onsite installation by 60%, ready for immediate operation.
- Scalability: Parallel skids to handle large flows (e.g., 10 skids for 50,000 m³/d).
- Space Efficiency: Compact footprint (2m×4m/set), 50% smaller than traditional systems.
- Low Maintenance: Auto-backwash (1–2% water loss per cycle), membrane lifespan 3–5 years with proper care.
Types
Applications
★ Drinking water pretreatment (removes turbidity, pathogens) and wastewater reuse (cooling tower make-up).
Industrial Processes
★ Electronics (ultra-pure water pretreatment), textiles (dye wastewater purification), and petrochemicals (process fluid filtration).
★ Milk concentration, wine clarification, and juice filtration to remove particulates and bacteria.
Emergency Water Supply
★ Portable UF skids (500–1,000 m³/d) for disaster areas, providing potable water from river/lake sources.
Design Considerations
Flow Rate: 1 m² membrane handles ~20 L/h (calculate membrane area based on target flow: e.g., 1,000 m³/d needs 2,000 m²).
Water Quality: High-SS feeds (≥50 mg/L) require pre-filtration (bag filters, 50μm) to protect membranes.
Temperature & Pressure:
- Max. 45°C for PVDF membranes; ceramic membranes suit high-temperature (≤120°C) applications.
- Operating pressure typically 0.1–0.5 MPa, adjusted by VFD-controlled pumps.
Automation Level:
- Basic skids with manual controls or fully automated systems with remote monitoring (PLC + SCADA integration).
ROCKERHILL Partial Ultrafiltration Membrane Project references
|
S/N |
Capacity |
Process |
Location |
Application |
Completion |
|
1 |
1000 m3/d |
UF+RO |
Henan gongyi, |
Power plant |
2024 |
|
2 |
1200m3/d |
UF+RO |
Anhui YueXi |
Sea water desalination |
2019 |
|
3 |
300m3/d |
UF+RO +EDI |
Henan zhengzhou |
Factory waste water |
2017 |
|
4 |
600m3/d |
UF+RO |
Tibet Lhasa |
Sea water desalination |
2020 |
|
5 |
1000m3/d |
UF+RO |
Jiang Xigao Ann |
Sea water desalination |
2021 |
|
6 |
1300m3/d |
UF+RO |
Oman |
Sea water desalination |
2024 |
|
7 |
600m3/h |
UF+RO +EDI |
Henan NaXiang |
Public water usage |
2023 |
|
8 |
800m3/h |
UF+RO +EDI |
Wuzhong, Ningxia |
Sea water desalination |
2020 |
|
9 |
500m3/h |
UF+RO |
Dali in yunnan province |
Power plant |
2019 |
|
10 |
10000 m3/d |
UF+RO |
Anhui province |
Industrial park |
2024 |
|
11 |
1000 m3/d |
UF+RO +EDI |
Anhui buried hill |
Sea water desalination |
2023 |
|
12 |
600m3/h |
UF+RO |
Morocco |
Sea water desalination |
2018 |
|
13 |
700t/h |
Inlet: Municipal water (turbidity 20 NTU) Outlet: Turbidity <0.5 NTU, 99.9% bacteria removal |
Tianjin |
Desalination |
2022 |
|
14 |
500t/h |
Inlet: River water (turbidity 15 NTU, organic matter) Outlet: Turbidity <0.8 NTU, 99% microbial removal, 70% COD reduction |
Zhengzhou Shifo |
Desalination |
2023 |
Hot Tags: uf skid, China uf skid manufacturers, suppliers, factory