Process Skid Insulation Specifications

Nov 17, 2026

Leave a message

Insulating a process skid means protecting its piping, equipment and enclosure so the process stays at the right temperature, nothing freezes, surfaces are safe to touch and condensation does not form. For a containerized skid in a cold climate, insulation works as a system: an insulated, heated and ventilated container; insulation on piping and equipment sized for the process temperature; heat tracing on lines that can freeze; and details that allow inspection and maintenance.

Insulation is often treated as a finishing item, but on a skid it affects layout, access, shipping, start-up and long-term corrosion. This guide covers the main design considerations and material options, and explains how ROCKERHILL approached insulation on its containerized CO2 carbon capture skid for a Canadian direct air capture project, a design shaped by extreme Canadian winters.

news-800-600
news-800-600

Why insulate a process skid?

Purpose

What it prevents

Typical locations on a skid

Freeze protection

Frozen and burst lines, blocked instruments

Water, condensate and drain lines, instrument impulse lines, dead legs

Process temperature control

Heat loss or gain that changes process performance

Hot gas lines, coolers, scrubbers, heated vessels

Condensation control

Moisture on cold surfaces, dripping, corrosion

Cold water and chilled lines, cold vessels

Personnel protection

Burns from hot surfaces

Compressor discharge, hot gas and steam lines

Energy saving

Wasted heating or cooling energy

All hot or cold service equipment

Noise reduction

High noise inside the enclosure

Compressor and vacuum pump piping

On a containerized skid, there is a second layer: the container itself must be insulated and heated so equipment, instruments and controls can start and run at very low outdoor temperatures.

Key design considerations

1. Define the design basis first

  • Minimum (and maximum) design ambient temperature at site
  • Required minimum container interior temperature
  • Operating, minimum and maximum temperature of each line and vessel
  • Which lines contain water or can collect condensate
  • Whether the skid will sit idle in winter (shutdown and restart conditions)
  • Hazardous area classification, which affects heaters and heat tracing

2. Container envelope, heating and ventilation

  • Insulated walls, roof and floor reduce heat loss and prevent condensation on the inside of the container.
  • Electric space heaters with thermostats keep the interior above a set minimum temperature.
  • Supply and exhaust ventilation removes equipment heat in summer and controls gas build-up, but every air change in winter is heat lost. Ventilation and heating must be designed together, with dampers or variable speed fans to limit cold air intake.
  • Penetrations for piping and cables must be sealed and insulated to avoid cold bridges.
  • Vent and relief lines routed outside the container need attention where they pass through the wall and at outlets, where condensate can freeze.

3. Piping and equipment insulation

  • Size insulation thickness for the process temperature and the worst-case ambient, using a heat loss calculation (for example ASTM C680 methods).
  • For hot surfaces, a common personnel protection target is a surface temperature that will not cause burns on brief contact; ASTM C1055 gives guidance.
  • For cold service, use a continuous vapor retarder to stop moisture entering the insulation.

4. Heat tracing

Insulation slows heat loss but does not stop freezing in a line with no flow. Lines that may sit stagnant (drains, condensate lines, instrument lines, standby branches) need heat tracing under the insulation.

Heat tracing type

Characteristics

Typical use

Self-regulating cable

Output falls as temperature rises; can overlap; simple

Freeze protection and low-temperature maintenance

Constant wattage cable

Fixed output per metre; needs control

Longer runs, higher maintain temperatures

Mineral insulated (MI) cable

High temperature and high output; robust

Hot process lines, high exposure temperatures

Heat tracing needs thermostats or controllers, monitoring of circuit faults, and certification for the site: in Canada, heating cables are covered by CSA C22.2 No. 130, and hazardous areas require suitably certified products.

5. Corrosion under insulation (CUI)

Water trapped under insulation corrodes carbon steel and can cause chloride stress cracking on austenitic stainless steel. Industry guidance such as AMPP SP0198 identifies carbon steel operating roughly between −4 °C and 175 °C, or cycling through this range, as most at risk. To reduce CUI:

  • Apply a suitable coating under insulation on carbon steel.
  • Use low-chloride insulation on stainless steel (for example meeting ASTM C795).
  • Seal jacketing joints and terminations, and avoid water traps.
  • Provide inspection ports at high-risk points.

6. Maintainability

  • Use removable insulation covers on valves, flanges, strainers and instruments.
  • Keep nameplates, drains, vents and test points accessible.
  • Mark flow direction and line identification on the jacketing.

7. Shipping and site completion

Insulation is normally installed in the factory, with field joints left uninsulated at module splits and tie-in points for completion on site. Protect jacketing and exposed ends during transport, and supply the materials and procedures for site completion.

Insulation material options

Material

Typical service range (approx.)

Strengths

Watch-outs

Mineral wool (stone wool)

Ambient to high temperatures

Non-combustible, economical, good acoustic performance

Absorbs water if jacketing fails; not for cold service

Calcium silicate

Medium to high temperatures

Rigid, strong, good for hot piping

Absorbs water; heavier

Cellular glass

Cryogenic to high temperatures

Closed cell, does not absorb water, non-combustible

Rigid, more fragile, higher cost

Flexible elastomeric foam (FEF)

Low to moderate temperatures

Closed cell, built-in vapor resistance, easy on small lines

Limited maximum temperature; combustibility ratings vary

Polyisocyanurate (PIR)

Low to moderate temperatures

Very low thermal conductivity for cold service

Needs vapor retarder and jacketing; combustible

Aerogel blanket

Very wide range

Thin layers, good where space is tight

Higher material cost

Removable insulation jackets

Depends on fill

Fast access to valves, flanges, instruments

Must be well fitted to avoid gaps

Jacketing (cladding)

Jacketing

Typical use

Aluminum sheet

General purpose, outdoor and indoor

Stainless steel sheet

Corrosive, fire-exposed or washdown areas

PVC or similar

Indoor, light-duty, cold service

Mastic or vapor retarder systems

Cold service, irregular shapes

Case study: insulation on ROCKERHILL's containerized CO2 capture skid for Canada

ROCKERHILL designed and built a containerized balance-of-plant skid for a CO2 direct air capture project in Canada, awarded in 2026 after an international competitive tender. The skid receives CO2 and condensate from the DAC units, cools and dries the gas in two cooling stages and two scrubbers, compresses it with a dry screw compressor and rejects heat through a closed cooling water loop to a multi-fan air cooler. It was built to the ASME pressure vessel code and CSA B51, with CRN registration through ABSA and cUL/CSA electrical components.

The site requirement was clear: equipment must start and run at very low ambient temperatures. ROCKERHILL's design response combined several measures:

  • Heated and ventilated container. Supply and exhaust fans and electric heaters keep the container interior above a set minimum temperature for winter operation.
  • Insulation sized for the process temperature. Process piping and equipment are insulated for both process-temperature control and extreme cold, so gas and condensate stay within their operating range.
  • Insulated piping with clear identification. Insulated lines, actuated valves and instruments carry flow-direction marking for safe operation and maintenance.
  • Freeze-protection heat tracing on lines at risk of freezing.
  • Material selections rated for extreme low-temperature operation.
  • Vent lines routed outside the container, keeping relief and vent discharges out of the enclosure.

About ROCKERHILL

ROCKERHILL is a designer and manufacturer of custom and containerized process skids, with references including an ASME-coded CO2 carbon capture skid for Canada, an H2O2 production skid for the USA, an ultrapure water skid for Seiko Epson in Singapore and a water treatment skid for BP Zhuhai. Every skid is factory tested before shipment and comes with commissioning support, training, a spare parts list and an 18-month warranty.